Certain Disk Drives May Experience Data Miscompare or Drive Initialization Issues



Category :AvailabilityData Loss
Release Phase :Resolved
Bug Id :6797158, 6779446  
Product :Sun Fire X4500 Server
Sun Fire X4540 Server
Sun Fire X2100 Server
Sun Fire X2100 M2 Server
Sun Fire X2200 M2 Server
Sun Fire X2250 Server
Sun Ultra24 Workstation
Sun Fire T1000 Server
Sun SPARC Enterprise T1000 Server
Sun Storage J4200 Array
Sun Storage J4400 Array
Sun Storage 7310 Unified Storage System
Sun Storage 7410 Unified Storage System  
Date of Resolved Release :31-Mar-2009 

Certain Disk Drives May Experience Data Miscompare or Drive Initialization Issues


1. Impact

Certain disk drives with disk firmware version SU0B may experience data integrity issues or drive intialization failure. There are two possible conditions associated with these drive firmware Bugs:

A. Disk drives may experience data miscompare errors, potentially affecting data integrity.
B. The affected drive may fail to initialize (hang) following power initialization and may not be visible to the system.

2. Contributing Factors

These issues can occur on the following disk drives:
  • ST32502NS (250.0GB) SATA Disk Drive (390-0411-02, 390-0411-03)
  • ST35002NS (500.0GB) SATA Disk Drive (390-0412-02)
  • ST37502NS (750.0GB) SATA Disk Drive (390-0413-02)
  • ST31000NS (1.0TB) SATA Disk Drive (390-0414-02)
with firmware version SUOB and without firmware version SU0D, for the following platforms:

Sun Fire X4500 and X4540
Sun Fire X2100 and X2100 M2 (250GB only), Sun Fire X2200 M2 (250GB only) , Sun Fire X2250 (250GB only)
Ultra24 (250GB only)
Sun Fire T1000 (250GB only), Sun SPARC Enterprise T1000 (250GB only)
Sun Storage J4200/J4400 Arrays (1 TB only)

To determine the firmware revision on the drive, run format(1M) with 'inquiry', as in the following examples:

example 1:
# format
Searching for disks...done
AVAILABLE DISK SELECTIONS:
      0. c0t0d0 <ATA-SEAGATEST31000N-SU0B cyl 60797 alt 2 hd 255 sec 126>
         /pci@0,0/pci1022,7458@1/pci11ab,11ab@1/disk@0,0
      1. c0t1d0 <ATA-SEAGATEST31000N-SU0B cyl 60797 alt 2 hd 255 sec 126>
         /pci@0,0/pci1022,7458@1/pci11ab,11ab@1/disk@1,0
      2. c0t2d0 <ATA-SEAGATEST31000N-SU0B cyl 60797 alt 2 hd 255 sec 126>
         /pci@0,0/pci1022,7458@1/pci11ab,11ab@1/disk@2,0
      3. c0t3d0 <ATA-SEAGATEST31000N-SU0B cyl 60797 alt 2 hd 255 sec 126>
          ...
     39. c5t4d0 <ATA-SEAGATEST31000N-SU0B cyl 60797 alt 2 hd 255 sec 126>
         /pci@2,0/pci1022,7458@8/pci11ab,11ab@1/disk@4,0
     40. c5t7d0 <ATA-SEAGATEST31000N-SU0B cyl 60797 alt 2 hd 255 sec 126>
         /pci@2,0/pci1022,7458@8/pci11ab,11ab@1/disk@7,0
Specify disk (enter its number):  40
selecting c5t7d0
[disk formatted]
FORMAT MENU:
       disk       - select a disk
       type       - select (define) a disk type
       partition  - select (define) a partition table
       current    - describe the current disk
       format     - format and analyze the disk
       fdisk      - run the fdisk program
       repair     - repair a defective sector
       label      - write label to the disk
       analyze    - surface analysis
       defect     - defect list management
       backup     - search for backup labels
       verify     - read and display labels
       save       - save new disk/partition definitions
       inquiry    - show vendor, product and revision
       volname    - set 8-character volume name
       !<cmd>     - execute <cmd>, then return
       quit
format> inquiry
Vendor:   ATA    
Product:  SEAGATE ST31000N
Revision: SU0B <---
example 2:
scsvr-56@[/]>format

Searching for disks...done
AVAILABLE DISK SELECTIONS:
      0. c2t0d0 <DEFAULT cyl 45597 alt 2 hd 255 sec 126>
         /pci@0,0/pci108e,534b@5/disk@0,0
      1. c2t1d0 <DEFAULT cyl 60797 alt 2 hd 255 sec 126>
         /pci@0,0/pci108e,534b@5/disk@1,0
Specify disk (enter its number): 1
selecting c2t1d0
[disk formatted]
FORMAT MENU:
       disk       - select a disk
       type       - select (define) a disk type
       partition  - select (define) a partition table
       current    - describe the current disk
       format     - format and analyze the disk
       fdisk      - run the fdisk program
       repair     - repair a defective sector
       label      - write label to the disk
       analyze    - surface analysis
       defect     - defect list management
       backup     - search for backup labels
       verify     - read and display labels
       save       - save new disk/partition definitions
       inquiry    - show vendor, product and revision
       volname    - set 8-character volume name
       !<cmd>     - execute <cmd>, then return
       quit
format> inquiry
Vendor:   ATA    
Product:  SEAGATE ST31000N
Revision: SU0B <---
format>
either of the above examples indicate the drive firmware revision is SU0B and requires upgrade to SU0D.

Alternatively, drives can be inspected visually for the Sun model number (as listed in Contributing Factors).

3. Symptoms

The data miscompare issue will not produce any visible symptoms and will not be detected by the drive or the host.

For the drive hang issue, the affected drive may fail to initialize following power initialization and may not be visible to the system.

4. Workaround

There is no workaround or avoidance for the data miscompare issue.

To avoid the drive hang issue, limit the number of power cycle events to the system until drive firmware can be upgraded.

5. Resolution

These issues are addressed in the following release:
  • Firmware SU0D (as delivered in patch 140698-01 or later) for the following drives:
  • ST32502NS (250.0GB) SATA Disk Drive (390-0411-02, 390-0411-03)
  • ST35002NS (500.0GB) SATA Disk Drive (390-0412-02)
  • ST37502NS (750.0GB) SATA Disk Drive (390-0413-02)
  • ST31000NS (1.0TB) SATA Disk Drive (390-0414-02)
for the following platforms:

Sun Fire X4500 and X4540
Sun Fire X2100 and X2100 M2 (250GB only), Sun Fire X2200 M2 (250GB only) , Sun Fire X2250 (250GB only)
Ultra24 (250GB only)
Sun Fire T1000 (250GB only), Sun SPARC Enterprise T1000 (250GB only)

To address this issue for ST31000NS (1.0TB) drives in J4200/J4400 arrays only, two CAM patches must be installed (platform update first followed by firmware update) due to dependencies between the platform and firmware carried forward from the -01 version of these patches. In order for the two patches to be installed, CAM must be running (or upgraded to) version 6.2 (or later) and can be downloaded from:

http://www.sun.com/download/index.jsp?cat=Systems%20Administration&tab=3&subcat=Storage%20Management

followed by application of the folllowing CAMS patches:
Installation of these patches will vary for each OS, and instructions can be found in the README file of each patch.  Shortly after these patches are installed, CAM will generate an alarm which will guide the admin through the upgrade process when desired.

If the J4400 is used as part of Sun Storage 7310/7410, upgrade to the latest appliance software image, which can obtained from:


The disk drive firmware is included and will be upgraded automatically.

Note:
Although the probability of occurrence for either condition is low, it is highly recommended that drive firmware be upgraded for all affected disks, regardless of system.

This Sun Alert notification is being provided to you on an "AS IS" basis. This Sun Alert notification may contain information provided by third parties. The issues described in this Sun Alert notification may or may not impact your system(s). Sun makes no representations, warranties, or guarantees as to the information contained herein. ANY AND ALL WARRANTIES, EXPRESS OR IMPLIED, INCLUDING WITHOUT LIMITATION WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, OR NON-INFRINGEMENT, ARE HEREBY DISCLAIMED. BY ACCESSING THIS DOCUMENT YOU ACKNOWLEDGE THAT SUN SHALL IN NO EVENT BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, PUNITIVE, OR CONSEQUENTIAL DAMAGES THAT ARISE OUT OF YOUR USE OR FAILURE TO USE THE INFORMATION CONTAINED HEREIN. This Sun Alert notification contains Sun proprietary and confidential information. It is being provided to you pursuant to the provisions of your agreement to purchase services from Sun, or, if you do not have such an agreement, the Sun.com Terms of Use. This Sun Alert notification may only be used for the purposes contemplated by these agreements.

Copyright 2000-2009 Sun Microsystems, Inc., 4150 Network Circle, Santa Clara, CA 95054 U.S.A. All rights reserved.


Modification History

13-Apr-2009: Added Category of Data Loss
17-Aug-2009: Updated Resolution section with Additional Info for 7310/7410




Attachments
This solution has no attachment

 
 
Login Required

You must login and have a valid contract to access Sun's Premium content which includes:

  • Sun Alerts
  • Bugs
  • Patches
  • Solutions
  • White Papers
  • Documentation
  • Support Knowledge

Login Required

You must login and have a valid contract to access Sun's contracted features

Access Legend:

(Login to access)   Sun Contracted Content
(Login to access)   Sun Contracted Feature

Please make use of SunSolve Feedback application by selecting the floating [+] to provide feedback about this specific document.

Search

Article Details
Article ID : 256068
Article Type : Sun Alert
Last reviewed : 2009-08-17
Audience : PUBLIC
Keywords :
Provide feedback  (help)
Page Tools
»  Print This Page
»  Email This Article
»  Bookmark This Article
 
Contact About Sun News & Events Employment Site Map Privacy Terms of Use Trademarks Copyright Sun Microsystems, Inc. | SunSolve Version 7.4.0 #1