Sun StorEdge 3510 Fiber Channel Array May Lose In-band Connectivity After Generating an Internal Disk Drive Command Transaction Timeout



Category :Availability
Release Phase :Resolved
Product :Sun StorageTek 3510 FC Array  
Bug Id :4892830  
Date of Resolved Release :21-AUG-2003 


Impact

Sun StorEdge 3510 Fiber Channel (FC) array may lose connectivity from the host or a logical drive initialization may fail.


Contributing Factors

This issue can occur in the following releases:

SPARC Platform

  • Sun StorEdge 3510 FC array with firmware version 3.27N or earlier

This issue only occurs after an internal disk drive command transaction timeout (error code "62F") has been generated.

To verify the firmware version, use the "telnet" or serial interface to the Sun StorEdge 3510 and select "View System Information" from the main menu.


Symptoms

Should the described issue occur, messages similar to the following are logged in the "/var/adm/messages" file, or in the Sun StorEdge 3510 event log:

    SCSI Drive ALERT: Unexpected Sense Received (62F)

Also, a logical drive initialization may fail with the same timeout error as shown above.


Workaround

There is no workaround. Please see the "Resolution" section below.


Resolution

This issue is addressed in the following release:

SPARC Platform

  • Sun StorEdge 3510 FC array with firmware version 3.27P (delivered with patch 113723-05) or later



Modification History




Attachments
This solution has no attachment

 
 
Login Required

You must login and have a valid contract to access Sun's Premium content which includes:

  • Sun Alerts
  • Bugs
  • Patches
  • Solutions
  • White Papers
  • Documentation
  • Support Knowledge

Login Required

You must login and have a valid contract to access Sun's contracted features

Access Legend:

(Login to access)   Sun Contracted Content
(Login to access)   Sun Contracted Feature

Please make use of SunSolve Feedback application by selecting the floating [+] to provide feedback about this specific document.

Search

Article Details
Article ID : 201706
Article Type : Sun Alert
Last reviewed : 2003-08-18
Audience : PUBLIC
Keywords :
Provide feedback  (help)
Page Tools
»  Print This Page
»  Email This Article
»  Bookmark This Article
 
Contact About Sun News & Events Employment Site Map Privacy Terms of Use Trademarks Copyright Sun Microsystems, Inc. | SunSolve Version 7.4.0 #1