DVD and CDR/W Drives on Sun Blade 2500 May Not Power Up |
|
| Category : | Availability |
| Release Phase : | Resolved |
| Product : | Sun Blade 2500 Workstation
|
| Bug Id : | 4836050
|
| Date of Resolved Release : | 16-JUL-2004
|
Impact
Due to incorrect jumper settings, DVD and CDR/W drives on Sun Blade 2500 systems that were shipped between 01-Mar-2004 and 01-May-2004, may not power up after the workstation recovers from "Power Management Mode".
Contributing Factors
This issue can occur on the following platform:
SPARC Platform
This issue only occurs on Sun Blade 2500 systems (shipped between 01-Mar-2004 and 01-May-2004) that have the jumper setting on the drive set to "Slave" or "Cable Select".
Note: Drives with the jumper set to "Master" will not experience this issue.
To verify if a system is vulnerable to this issue, a visual inspection of the drive is required to determine the jumper settings.
Symptoms
If the described issue occurs, messages similar to the following are logged to "/var/adm/messages" file:
<date> <system>: [ID 568058 kern.warning] WARNING: Drive not ready before
set_features
<date> <system> last message repeated 2 times
<date> <system>: [ID 352328 kern.warning] WARNING: ata_controller
- Can not reset Secondary channel
<date> <system>: [ID 405830 kern.warning] WARNING: Device sd30 failed to
power up.
<date> <system>: [ID 749148 kern.warning] WARNING: Please see your system
administrator or reboot
Workaround
To work around the described issue, change the jumper setting on the drive to "Master" by doing the following:
-
Refer to the back panel of the drive for the jumper setting map
-
Remove the jumper from the "Slave" or "Cable Select" setting and move it to the "Master"configuration
-
Reboot the system
Resolution
This issue has been addressed and the jumper settings have been corrected on all drives shipped after 01-May-2004.