Certain FCAL Disk Drives For the Sun StorEdge T3+ Array May Go Offline



Category :Availability
Release Phase :Resolved
Product :Sun StorageTek T3 Array
Sun StorageTek T3+ Array  
Bug Id :5065023  
Date of Resolved Release :30-NOV-2004 


Impact

In the Sun StorEdge T3+ array with drive firmware version 1504, disk types MAN3367FC (36.4GB FCAL) and MAN3735FC (73.4GB FCAL) may go offline.


Contributing Factors

This issue can occur on the following drive types:

  • Internal Disk Drives MAN3367FC (36.4GB FCAL) and MAN3735FC (73.4GB FCAL) with firmware revision 1504

on the following platform:

  • Sun StorEdge T3+ with firmware revision 3.1.4 and without firmware (3.1.5) patch 115180-07

If a disk has gone offline, messages similar to the following will be reported in "/var/adm/messages":

    Nov 23 03:54:59 seine-t3-12 LPCT[1]: N: u1d07: Not ready on loop 1
    Nov 23 03:55:00 seine-t3-12 LPCT[1]: N: u1d07: Not ready on loop 2
    Nov 23 03:55:15 seine-t3-12 ISR1[1]: W: u1d07 SVD_PATH_FAILOVER: path_id = 0
    Nov 23 03:55:31 seine-t3-12 ISR1[1]: N: u1d07 SVD_RETRY: Retries Exhausted (ccb = 0x18c9f4c)
    Nov 23 03:55:31 seine-t3-12 ISR1[1]: N: u1d07 SVD_DONE: Command Error = 0x4
    Nov 23 03:55:31 seine-t3-12 ISR1[1]: N: u1d07 SVD_RETRY: Retries Exhausted (ccb = 0x18c87ec)
    Nov 23 03:55:31 seine-t3-12 ISR1[1]: N: u1d07 SVD_DONE: Command Error = 0x4
    Nov 23 03:55:31 seine-t3-12 ISR1[1]: N: u1d07 sid 287454 stype 4003 disk error 4
    Nov 23 03:55:47 seine-t3-12 ISR1[1]: W: u1d07 SVD_PATH_FAILOVER: path_id = 1
    Nov 23 03:56:05 seine-t3-12 ISR1[1]: N: u1d07 SVD_RETRY: Retries Exhausted (ccb = 0x18c7b2c)
    Nov 23 03:56:05 seine-t3-12 ISR1[1]: N: u1d07 SVD_DONE: Command Error = 0x4
    Nov 23 03:56:05 seine-t3-12 ISR1[1]: N: u1d07 SVD_RETRY: Retries Exhausted (ccb = 0x18d010c)
    Nov 23 03:56:05 seine-t3-12 ISR1[1]: N: u1d07 SVD_DONE: Command Error = 0x4
    Nov 23 03:56:05 seine-t3-12 ISR1[1]: N: u1d07 sid 287454 stype 4003 disk error 4
    Nov 23 03:56:05 seine-t3-12 ANNT[1]: W: u1d07: Failed
    Nov 23 03:56:05 seine-t3-12 ISR1[1]: N: u1d07 sid 287455 stype 4003 disk error 3
    Nov 23 03:56:08 seine-t3-12 LPCT[1]: N: u1d07: Bypassed on loop 1
    Nov 23 03:56:09 seine-t3-12 LPCT[1]: N: u1d07: Bypassed on loop 2
    Nov 23 03:56:12 seine-t3-12 LT00[1]: N: u1d07 Reconstruction to standby disk started
    Nov 23 03:56:12 seine-t3-12 LT00[1]: N: u1d07 Reconstruction to standby drive failed

Symptoms

The drive will go offline and will no longer be available to the system. There are no other indications that this condition has occurred.


Workaround

There is no workaround for this issue. Please see the "Resolution" section below.


Resolution

This issue is resolved on the following drive types:

  • Internal Disk Drives MAN3367FC (36.4GB FCAL) and MAN3735FC (73.4GB FCAL) (with firmware revision 1504)

on the following platform:

  • Sun StorEdge T3+ with firmware (3.1.5) patch 115180-07 or later

Note: Only the single patch listed is necessary to resolve this issue, as the firmware for both the drives and controllers are embedded in the controller firmware on the T3+ platform.




Modification History




Attachments
This solution has no attachment

 
 
Login Required

You must login and have a valid contract to access Sun's Premium content which includes:

  • Sun Alerts
  • Bugs
  • Patches
  • Solutions
  • White Papers
  • Documentation
  • Support Knowledge

Login Required

You must login and have a valid contract to access Sun's contracted features

Access Legend:

(Login to access)   Sun Contracted Content
(Login to access)   Sun Contracted Feature

Please make use of SunSolve Feedback application by selecting the floating [+] to provide feedback about this specific document.

Search

Article Details
Article ID : 201000
Article Type : Sun Alert
Last reviewed : 2004-11-15
Audience : PUBLIC
Keywords :
Provide feedback  (help)
Page Tools
»  Print This Page
»  Email This Article
»  Bookmark This Article
 
Contact About Sun News & Events Employment Site Map Privacy Terms of Use Trademarks Copyright Sun Microsystems, Inc. | SunSolve Version 7.4.0 #1