Certain FCAL Disk Drives For the Sun StorEdge T3+ Array May Go Offline |
|
| Category : | Availability |
| Release Phase : | Resolved |
| Product : | Sun StorageTek T3 Array Sun StorageTek T3+ Array
|
| Bug Id : | 5065023
|
| Date of Resolved Release : | 30-NOV-2004
|
Impact
In the Sun StorEdge T3+ array with drive firmware version 1504, disk types MAN3367FC (36.4GB FCAL) and MAN3735FC (73.4GB FCAL) may go offline.
Contributing Factors
This issue can occur on the following drive types:
-
Internal Disk Drives MAN3367FC (36.4GB FCAL) and MAN3735FC (73.4GB FCAL) with firmware revision 1504
on the following platform:
-
Sun StorEdge T3+ with firmware revision 3.1.4 and without firmware (3.1.5) patch 115180-07
If a disk has gone offline, messages similar to the following will be reported in "/var/adm/messages":
Nov 23 03:54:59 seine-t3-12 LPCT[1]: N: u1d07: Not ready on loop 1
Nov 23 03:55:00 seine-t3-12 LPCT[1]: N: u1d07: Not ready on loop 2
Nov 23 03:55:15 seine-t3-12 ISR1[1]: W: u1d07 SVD_PATH_FAILOVER: path_id = 0
Nov 23 03:55:31 seine-t3-12 ISR1[1]: N: u1d07 SVD_RETRY: Retries Exhausted (ccb = 0x18c9f4c)
Nov 23 03:55:31 seine-t3-12 ISR1[1]: N: u1d07 SVD_DONE: Command Error = 0x4
Nov 23 03:55:31 seine-t3-12 ISR1[1]: N: u1d07 SVD_RETRY: Retries Exhausted (ccb = 0x18c87ec)
Nov 23 03:55:31 seine-t3-12 ISR1[1]: N: u1d07 SVD_DONE: Command Error = 0x4
Nov 23 03:55:31 seine-t3-12 ISR1[1]: N: u1d07 sid 287454 stype 4003 disk error 4
Nov 23 03:55:47 seine-t3-12 ISR1[1]: W: u1d07 SVD_PATH_FAILOVER: path_id = 1
Nov 23 03:56:05 seine-t3-12 ISR1[1]: N: u1d07 SVD_RETRY: Retries Exhausted (ccb = 0x18c7b2c)
Nov 23 03:56:05 seine-t3-12 ISR1[1]: N: u1d07 SVD_DONE: Command Error = 0x4
Nov 23 03:56:05 seine-t3-12 ISR1[1]: N: u1d07 SVD_RETRY: Retries Exhausted (ccb = 0x18d010c)
Nov 23 03:56:05 seine-t3-12 ISR1[1]: N: u1d07 SVD_DONE: Command Error = 0x4
Nov 23 03:56:05 seine-t3-12 ISR1[1]: N: u1d07 sid 287454 stype 4003 disk error 4
Nov 23 03:56:05 seine-t3-12 ANNT[1]: W: u1d07: Failed
Nov 23 03:56:05 seine-t3-12 ISR1[1]: N: u1d07 sid 287455 stype 4003 disk error 3
Nov 23 03:56:08 seine-t3-12 LPCT[1]: N: u1d07: Bypassed on loop 1
Nov 23 03:56:09 seine-t3-12 LPCT[1]: N: u1d07: Bypassed on loop 2
Nov 23 03:56:12 seine-t3-12 LT00[1]: N: u1d07 Reconstruction to standby disk started
Nov 23 03:56:12 seine-t3-12 LT00[1]: N: u1d07 Reconstruction to standby drive failed
Symptoms
The drive will go offline and will no longer be available to the system. There are no other indications that this condition has occurred.
Workaround
There is no workaround for this issue. Please see the "Resolution" section below.
Resolution
This issue is resolved on the following drive types:
-
Internal Disk Drives MAN3367FC (36.4GB FCAL) and MAN3735FC (73.4GB FCAL) (with firmware revision 1504)
on the following platform:
-
Sun StorEdge T3+ with firmware (3.1.5) patch 115180-07 or later
Note: Only the single patch listed is necessary to resolve this issue, as the firmware for both the drives and controllers are embedded in the controller firmware on the T3+ platform.
Modification History
AttachmentsThis solution has no attachment