Using sccli(1M) to Manage a Sun StorEdge 3510 Fiber Channel Array May Cause Sun StorEdge 6910/6960 LUNs to Disappear |
|
| Category : | Availability |
| Release Phase : | Resolved |
| Product : | Sun StorageTek 3510 FC Array Sun StorageTek 6910 Sun StorageTek 6960
|
| Bug Id : | 4878805
|
| Date of Workaround Release : | 19-AUG-2003
|
| Date of Resolved Release : | 20-OCT-2003
|
Impact
Temporary loss of Sun StorEdge 6910/6960 LUNs may occur when using sccli(1M) to manage a Sun StorEdge 3510 Fiber Channel (FC) Array from a host that also has a Sun StorEdge 6910/6960 in the configuration.
Contributing Factors
This issue can occur in the following platforms:
SPARC Platform
-
Sun StorEdge 3510 FC Array without patch 113725-01
The described issue only occurs if all of the the following are true:
-
sccli(1M) (version 1.2.6 or earlier) is used to manage a Sun StorEdge 3510 FC Array, and
-
sccli(1M) is used on the same data host connected to the Sun StorEdge 6910/6960, and
-
A Sun StorEdge 6910/6960 is connected to the same data host as the Sun StorEdge 3510 host, and
-
The Sun StorEdge 6910/6960 system is running firmware 8.01 and earlier
To determine the version of "sccli", run the following command:
# sccli -v
sccli version 1.2.6
Use the "showsc -v" command to display the firmware version of the system controller.
Symptoms
Should the described issue occur, messages similar to the following are logged to the "/var/adm/messages" file:
May 26 10:07:33 mktgsumm fp: [ID 517869 kern.warning] WARNING: fp(1): GPN_ID for
D_ID=108800 failed
May 26 10:07:33 mktgsumm fp: [ID 517869 kern.warning] WARNING: fp(1): N_x Port
with D_ID=108800, PWWN=2b000060220042c2 disappeared from fabric
Workaround
There is no workaround. Please see the "Resolution" section below.
Resolution
This issue is addressed in the following releases:
-
Sun StorEdge 3510 FC Array with patch 113725-01 or later
Modification HistoryDate: 20-OCT-2003
-
Status Resolved
-
Updated Contributing Factors and Resolution sections
AttachmentsThis solution has no attachment