Sun StorEdge 3510/3511 Arrays May Fail to Boot Upon Reset/Power Cycle When Connected in a Sun Cluster 3.x Environment With 3+ Nodes |
|
| Category : | Availability |
| Release Phase : | Resolved |
| Product : | Sun StorageTek 3510 FC Array Sun StorageTek 3511 SATA Array
|
| Bug Id : | 6276668
|
| Date of Workaround Release : | 15-AUG-2005
|
| Date of Resolved Release : | 02-SEP-2005
|
Impact
Sun StorEdge 3510/3511 arrays may fail to boot upon a reset/power cycle when connected in a Sun Cluster 3.x environment with 3+ nodes.
Contributing Factors
This issue can occur on the following platforms:
SPARC Platform
- Sun StorEdge 3510 FC array with firmware version 4.11I (as delivered in patch 113723-10) and without patch 113723-11
- Sun StorEdge 3511 FC array with firmware version 4.11I (as delivered in patch 113724-04) and without patch 113724-05
This issue will only occur in multi host configurations that issue SCSI-3 disk reservations from multiple nodes, including:
- Sun Cluster 3.x on Solaris 8, Solaris 9 and Solaris 10
and other configurations that share the Sun StorEdge 3500/3511 array among more than two host systems.
Symptoms
Should the described issue occur, the system will fail to boot upon a system reset or power cycle, and messages similar to the following will be seen on the serial port connection to the array:
========================================================================
Restoring saved persistent reservations.
Preparing to restore saved persistent reservations. Type 'skip' to skip:
========================================================================
In this example, the SE3510 tries to restore the persistent reservation but due to this issue, it can not boot and the following error is received:
=============================================
Unrecoverable Controller Error Encountered !
Resetting Controller !
Unrecoverable Controller Error Encountered !
Resetting Controller !
=============================================
Workaround
There is no workaround. Please see the "Resolution" section below.
Resolution
This issue is addressed in the following releases:
- Sun StorEdge 3510 FC array with patch 113723-11 or later
- Sun StorEdge 3511 FC array with patch 113724-05 or later
Modification HistoryDate: 02-SEP-2005
Change History
- State: Resolved
- Updated Contributing Factors, Relief/Workaround and Resolution sections
AttachmentsThis solution has no attachment