Sun StorEdge 3310 SCSI Array and 3510/3511 FC Array Event Hardware Failure Messages May Result in Incorrect FRU Replacement



Category :Availability
Release Phase :Resolved
Product :Sun StorageTek 3310 SCSI Array
Sun StorageTek 3510 FC Array
Sun StorageTek 3511 SATA Array  
Bug Id :4995551  
Date of Workaround Release :18-MAR-2005 
Date of Resolved Release :29-AUG-2005 


Impact

Event hardware failure messages without a unique FRU identifier may result in the replacement of the wrong FRU on a Sun StorEdge 3310 SCSI or 3510/3511 FC array.

The serial number in the event messages is always the serial number of the primary controller regardless of which CPU has the fault. As a result, the good FRU that matches the serial number may incorrectly be replaced while the bad FRU remains in the system. If an event occurs on the bad controller at the time the good controller is being replaced, a full array outage is possible.


Contributing Factors

This issue can occur on the following platforms:

SPARC Platform

  • Sun StorEdge 3310 SCSI Array without patch 113722-10
  • Sun StorEdge 3510 FC Array without patch 113723-10
  • Sun StorEdge 3511 FC Array without patch 113724-04

Symptoms

Example event messages:

    [0123] #298: StorEdge Array SN#26103 Peripheral Device ALERT: CPU high
    temperature threshold exceeded ( 96.00C)

    Mon Feb 14 12:45:31 2005 [01A3] #299: StorEdge Array SN#26103 Peripheral
    Device NOTICE: CPU temperature high temperature now back to non-critical
    level ( 92.00C)

Based upon the serial number, the primary controller was replaced. The above messages are from the primary controller AFTER the replacement, indicating that the wrong FRU was replaced. Aside from the serial number, there is no identifying FRU information contained in the message.


Workaround

There is no workaround. Please see the "Resolution" section below.


Resolution

This issue is addressed in the following releases:

SPARC Platform

  • Sun StorEdge 3310 SCSI Array with patch 113722-10 or later
  • Sun StorEdge 3510 FC Array with patch 113723-10 or later
  • Sun StorEdge 3511 FC Array with patch 113724-04 or later



Modification History


Date: 16-MAY-2005
  • Updated Contributing Factors and Resolution sections

Date: 14-JUN-2005

14-Jun-2005:

  • Updated Contributing Factors

Date: 16-JUN-2005
  • Updated Contributing Factors and Resolution sections

Date: 29-AUG-2005
  • State: Resolved
  • Updated Contributing Factors and Resolution sections



Attachments
This solution has no attachment

 
 
Login Required

You must login and have a valid contract to access Sun's Premium content which includes:

  • Sun Alerts
  • Bugs
  • Patches
  • Solutions
  • White Papers
  • Documentation
  • Support Knowledge

Login Required

You must login and have a valid contract to access Sun's contracted features

Access Legend:

(Login to access)   Sun Contracted Content
(Login to access)   Sun Contracted Feature

Please make use of SunSolve Feedback application by selecting the floating [+] to provide feedback about this specific document.

Search

Article Details
Article ID : 200432
Article Type : Sun Alert
Last reviewed : 2006-11-06
Audience : PUBLIC
Keywords :
Provide feedback  (help)
Page Tools
»  Print This Page
»  Email This Article
»  Bookmark This Article
 
Contact About Sun News & Events Employment Site Map Privacy Terms of Use Trademarks Copyright Sun Microsystems, Inc. | SunSolve Version 7.4.0 #1