Sun StorEdge 3310 SCSI Array and 3510/3511 FC Array Event Hardware Failure Messages May Result in Incorrect FRU Replacement |
|
| Category : | Availability |
| Release Phase : | Resolved |
| Product : | Sun StorageTek 3310 SCSI Array Sun StorageTek 3510 FC Array Sun StorageTek 3511 SATA Array
|
| Bug Id : | 4995551
|
| Date of Workaround Release : | 18-MAR-2005
|
| Date of Resolved Release : | 29-AUG-2005
|
Impact
Event hardware failure messages without a unique FRU identifier may result in the replacement of the wrong FRU on a Sun StorEdge 3310 SCSI or 3510/3511 FC array.
The serial number in the event messages is always the serial number of the primary controller regardless of which CPU has the fault. As a result, the good FRU that matches the serial number may incorrectly be replaced while the bad FRU remains in the system. If an event occurs on the bad controller at the time the good controller is being replaced, a full array outage is possible.
Contributing Factors
This issue can occur on the following platforms:
SPARC Platform
- Sun StorEdge 3310 SCSI Array without patch 113722-10
- Sun StorEdge 3510 FC Array without patch 113723-10
- Sun StorEdge 3511 FC Array without patch 113724-04
Symptoms
Example event messages:
[0123] #298: StorEdge Array SN#26103 Peripheral Device ALERT: CPU high
temperature threshold exceeded ( 96.00C)
Mon Feb 14 12:45:31 2005 [01A3] #299: StorEdge Array SN#26103 Peripheral
Device NOTICE: CPU temperature high temperature now back to non-critical
level ( 92.00C)
Based upon the serial number, the primary controller was replaced. The above messages are from the primary controller AFTER the replacement, indicating that the wrong FRU was replaced. Aside from the serial number, there is no identifying FRU information contained in the message.
Workaround
There is no workaround. Please see the "Resolution" section below.
Resolution
This issue is addressed in the following releases:
SPARC Platform
- Sun StorEdge 3310 SCSI Array with patch 113722-10 or later
- Sun StorEdge 3510 FC Array with patch 113723-10 or later
- Sun StorEdge 3511 FC Array with patch 113724-04 or later
Modification HistoryDate: 16-MAY-2005
-
Updated Contributing Factors and Resolution sections
Date: 14-JUN-2005
14-Jun-2005:
- Updated Contributing Factors
Date: 16-JUN-2005
- Updated Contributing Factors and Resolution sections
Date: 29-AUG-2005
- State: Resolved
- Updated Contributing Factors and Resolution sections
AttachmentsThis solution has no attachment