Logical Volumes Created With 3.27x Firmware Are Incompatible with 4.11I Firmware



Category :Data Loss
Release Phase :Resolved
Product :Sun StorageTek 3510 FC Array
Sun StorageTek 3511 SATA Array  
Bug Id :6274609  
Date of Workaround Release :09-JUN-2005 
Date of Resolved Release :30-SEP-2005 


Impact

When upgrading from 3.27x to 4.11I and using Logical Volumes (LV) in a Storedge 3510FC array or 3511FC array (SATA), the system will experience the following issue: data sent to the Logical Volume in the array will not destage from cache to the logical volume(s), resulting in loss of access to the array and possible loss of data. 


Contributing Factors

This issue can occur on the following platforms:

  • Sun StorEdge 3510 FC array with firmware revision 4.11I and without firmware revision 4.13c (as delivered in patch 113723-11)
  • Sun StorEdge 3511 FC array (SATA) with firmware revision 4.11I and without firmware revision 4.13c (as delivered in patch 113724-05)

This issue is seen immediately after the firmware upgrade from 3.27x to 4.11I.

Notes:

  1. Only existing 3.27x Logical Volumes are affected.
  2. New Logical Volumes created on 4.11I do not experience this issue.
  3. Logical partitions and logical drives do not experience this issue.
  4. An array upgraded to 4.11I WITHOUT Logical Volumes does not experience this issue.

Symptoms

Following the firmware upgrade from 3.27x to 4.11I, access to the array will be lost. I/O sent to the Logical Volumes while the array was at 4.11I may be lost or corrupted.


Workaround

To work around the described issue, one of the two following remedies can be used (use only one of these workarounds):

A) For use prior to an upgrade (recommended):

Note: This is a preventative measure when using Logical Volumes on a 3510FC or 3511FC with SATA that is to be upgraded. Follow these steps:

  1. Back up data existing on the Logical Volume(s) to tape or to a filesystem which is not located on the array being updated.
  2. Remove the Logical Volume.
  3. Upgrade the firmware using normal procedures listed in the upgrade patch README file.
  4. Recreate the Logical Volumes on the upgraded array.
  5. Restore the data from the remote location or tape.

B) If the condition already exists:

Note: This procedure should be used to recover access to the array after an upgrade to 4.11I and seeing access and cache issues.

  1. To gain access to the array, the firmware must be downgraded to the latest 3.27x firmware.
  2. Use fsck(1M) to check the filesystem before mounting.
  3. When the data is checked and available, workaround "A" could be used to upgrade to 4.11I.

Resolution

This issue is addressed on the following platforms:

  • Sun StorEdge 3510 FC array with firmware revision 4.13c (as delivered in patch 113723-11 or later)
  • Sun StorEdge 3511 FC array (SATA) with firmware revision 4.13c (as delivered in patch 113724-05 or later)



Modification History


Date: 30-SEP-2005

30-Sep-2005:

  • Updated Contributing Factors and Resolution sections, re-release as Resolved



Attachments
This solution has no attachment

 
 
Login Required

You must login and have a valid contract to access Sun's Premium content which includes:

  • Sun Alerts
  • Bugs
  • Patches
  • Solutions
  • White Papers
  • Documentation
  • Support Knowledge

Login Required

You must login and have a valid contract to access Sun's contracted features

Access Legend:

(Login to access)   Sun Contracted Content
(Login to access)   Sun Contracted Feature

Please make use of SunSolve Feedback application by selecting the floating [+] to provide feedback about this specific document.

Search

Article Details
Article ID : 200245
Article Type : Sun Alert
Last reviewed : 2005-09-30
Audience : PUBLIC
Keywords :
Provide feedback  (help)
Page Tools
»  Print This Page
»  Email This Article
»  Bookmark This Article
 
Contact About Sun News & Events Employment Site Map Privacy Terms of Use Trademarks Copyright Sun Microsystems, Inc. | SunSolve Version 7.4.0 #1