A Limited Subset of DIMMs (less than 1%) Shipped in 2001-2002 May Have a Reliability Issue |
|
| Category : | Availability |
| Release Phase : | Resolved |
| Product : | Sun Fire 12K Server Sun Blade 2000 Workstation Sun Fire 280R Server Sun Fire V880 Server Netra 20 Server Sun Fire 3800 Server Sun Fire 4800 Server Sun Fire 4810 Server Sun Fire 6800 Server Sun Fire 15K Server Sun Blade 1000 Workstation Sun Fire V1280 Server Sun Fire V480 Server
|
| Bug Id : | 5034665
|
| Date of Workaround Release : | 29-MAR-2005
|
| Date of Resolved Release : | 13-SEP-2005
|
Impact
Based on analysis of long term field reliability, Sun has determined that a limited subset of DIMMs shipped in 2001 and 2002 (less than one percent of the installed base) may begin to show reduced reliability after approximately two years of operation. This reliability issue manifests itself in the form of both UEs (Uncorrectable Errors) and CEs (Correctable Errors) originating from the DIMM. The reliability of these DIMMs is normal for approximately the first two years of use, after which they may start to degrade below the expected level.
This lower reliability is due to a specific component issue and not all supply is impacted. Sun understands the issue and will be replacing the components at risk.
Contributing Factors
This issue can occur with the following DIMM product releases:
-
501-5401 256MB
-
501-6175 256MB
-
501-5030 512MB
-
501-6174 512MB
-
501-6109 1GB
-
501-5031 1GB
-
501-6173 1GB
on the following platforms (in particular, systems that shipped between 01/01/01 through 12/31/02 are most likely to have the suspect DIMMs):
-
Netra 20
-
Sun Fire V480, V880, V1280
-
Sunblade 1000, 2000
-
Sun Fire 280R
-
Sun Fire 3800, 4800, 4810, 6800
-
Sun Fire 12K, 15K
The cause of the UEs and CEs originates from an issue with one of the devices on the DIMM. This device issue will cause the DIMM to lose synchronization, resulting in incorrect data being sent to the system. The normal error correcting code within Solaris, or ECC, per the designed behavior will flag the incorrect data as a UE or, less often, as a CE, and prevent the system from using the incorrect data; data integrity is maintained.
Symptoms
When affected by this issue the system will experience CE and UE DIMM errors.
Workaround
Your Sun Services Representative has been provided procedures to identify impacted systems. If your system experiences a memory issue as described above, please check with your Services Team to determine if your systems are impacted.
Resolution
This issue is being addressed with the implementation of a Field Change Order (FCO). If you are concerned that your operation may be affected by this issue, please contact your local Sun Services representative to discuss an action plan.
Modification HistoryDate: 18-AUG-2005
18-aug-2005:
- Update Resolution section
Date: 13-SEP-2005
13-Sep-2005:
- Update Resolution section, re-release as Resolved
AttachmentsThis solution has no attachment