Solaris CAM 6.5.0 Firmware Release for 2510 2530 2540 J4200 J4400 J4500 |
Status: RELEASED
Patch Id: 142798-01
***********************************************************************
READ THE TERMS OF THE AGREEMENT ("AGREEMENT") IN THE LEGAL_LICENSE.TXT
FILE CAREFULLY BEFORE USING THIS SOFTWARE. BY USING THE SOFTWARE, YOU
AGREE TO THE TERMS OF THIS AGREEMENT. IF YOU DO NOT AGREE TO ALL OF THE
TERMS, PROMPTLY DESTROY THE UNUSED SOFTWARE.
***********************************************************************
For further information on patching best practices and resources, please
see the Big Admin Patching Center, http://www.sun.com/bigadmin/patches/
***********************************************************************Summary: Solaris CAM 6.5.0 Firmware Release for 2510 2530 2540 J4200 J4400 J4500
Date: Oct/23/2009
Installation Requirements:
NA
Solaris Release: 8 9 10
Sun OS Release: 5.8 5.9 5.10
Unbundled Product: Sun StorageTek Common Array Mgr Firmware Updates
Unbundled Release: 6.5.0
Xref:
Topic:
Relevant Architecture: all
BugId's fixed with this patch:
6788253 6844287 6884638 6884639
Changes incorporated in this version:
Patches accumulated and obsoleted by this patch:
Patches which conflict with this patch:
Required Patches:
Obsoleted by:
Files Included in this Patch:
/opt/SUNWstkcam/share/fw/README_2500.txt
/opt/SUNWstkcam/share/fw/README_J4000.txt
/opt/SUNWstkcam/share/fw/baseline/2510_exmoor.properties
/opt/SUNWstkcam/share/fw/baseline/2530_exmoor.properties
/opt/SUNWstkcam/share/fw/baseline/2540_exmoor.properties
/opt/SUNWstkcam/share/fw/baseline/j4200.properties
/opt/SUNWstkcam/share/fw/baseline/j4400.properties
/opt/SUNWstkcam/share/fw/baseline/j4500.properties
/opt/SUNWstkcam/share/fw/images/disk/ST31000NS.SU0E.fw
/opt/SUNWstkcam/share/fw/images/disk/ST32502NS.SU0E.fw
/opt/SUNWstkcam/share/fw/images/disk/ST35002NS.SU0E.fw
/opt/SUNWstkcam/share/fw/images/disk/ST37502NS.SU0E.fw
/opt/SUNWstkcam/share/fw/images/nge/RC_07355010_exmoor_apollo_133x.dlp
/opt/SUNWstkcam/share/fw/images/nge/RC_07355010_exmoor_apollo_1532.dlp
/opt/SUNWstkcam/share/fw/images/nge/RC_07355010_exmoor_apollo_1932.dlp
/opt/SUNWstkcam/share/fw/images/nge/esm0196.esm
Problem Description:
6788253 Cougar HBA hangs under load , aac driver resets HBA
6844287 Controller reboot due to Exception Data Abort in TcpService
6884638 Inband getChangeState requests fill all UTM structures
6884639 ECC errors on one controller cause outage to the alternate controller
Revision History:
142798-01:
2510/2530/2540 Firmware
Controller:
RC_07355010_exmoor_apollo_133x.dlp
RC_07355010_exmoor_apollo_1532.dlp
RC_07355010_exmoor_apollo_1932.dlp
IOM:
esm0196.esm
J4200/J4400 Firmware
Disk Drive:
ST31000NS.SU0E.fw
ST32502NS.SU0E.fw
ST35002NS.SU0E.fw
ST37502NS.SU0E.fw
J4500 Firmware
Disk Drive:
ST31000NS.SU0E.fw
ST35002NS.SU0E.fw
ST37502NS.SU0E.fwRevision History:
Patch Installation Instructions:
--------------------------------
See Special Install Instructions.
Special Install Instructions:
-----------------------------
*** PRE-REQUISITE:
*** Sun StorageTek Common Array Manager management host software
*** 6.5.0 installed.
***
1) Login to the Management Host as root user.
2) Download this patch to a download directory. Extract the patch using
the appropriate archive tool. Do not extract the patch in the /root
directory on an OpenSolaris host.
3) For details on this release, go to:
http://docs.sun.com/app/docs/coll/cam6.5
and select the link:
Sun StorageTek Common Array Manager Software 6.5.0 Release Notes
4) Apply the patch:
To install the patch on Solaris Hosts:
/usr/sbin/patchadd 142798-01
To install the patch on OpenSolaris Hosts:
1. Go into the patch directory.
cd <extraction location>/142798-01
2. Install the patched packages
pkgadd -Gd . SUNWc2500
pkgadd -Gd . SUNWj4000
Reply "y" to the two prompts:
The following files are already installed on the system and are being
used by another package:
/opt/SUNWstkcam/share/fw <attribute change only>
/opt/SUNWstkcam/share/fw/baseline <attribute change only>
/opt/SUNWstkcam/share/fw/images <attribute change only>
/opt/SUNWstkcam/share/fw/images/nge <attribute change only>
Do you want to install these conflicting files [y,n,?,q]
This package contains scripts which will be executed with super-user
permission during the process of installing this package.
Do you want to continue with the installation of <SUNWc2500> [y,n,?]
3. The following error message can be ignored for each package:
/var/sadm/pkg/SUNWc2500/save/142798-01/undo: -- file unchanged
compress(1) returned error code 2
The SUNWc2500 backout package will not be compressed.
5) Upgrade the array firmware using the Common Array Manager:
https://<this host ip address>:6789
Uninstalling the Patch:
------------------------------
Uninstalling firmware patches is generally not recommended. After upgrading
the array firmware and then backing out the patch, future analysis will
recommend the firmware be downgraded and generate an alarm. Firmware
downgrade is not supported in CAM. This should not be done without guidance
from a Sun Service representative.
README -- Last modified date: Friday, October 23, 2009