T3 1.18.04: System Firmware Update


Status: RELEASED
Patch Id: 109115-17
***********************************************************************
READ THE TERMS OF THE AGREEMENT ("AGREEMENT") IN THE LEGAL_LICENSE.TXT
FILE CAREFULLY BEFORE USING THIS SOFTWARE. BY USING THE SOFTWARE, YOU
AGREE TO THE TERMS OF THIS AGREEMENT. IF YOU DO NOT AGREE TO ALL OF THE
TERMS, PROMPTLY DESTROY THE UNUSED SOFTWARE.
***********************************************************************
Summary: T3 1.18.04: System Firmware Update
Date:  Sep/22/2004
Installation Requirements:
Additional instructions may be listed below
Solaris Release: 2.6 7 8 9 10
Sun OS Release: 5.6 5.7 5.8 5.9 5.10
Unbundled Product: T3 Firmware
Unbundled Release: 1.18.04
Xref: 
Topic: 
Relevant Architecture: sparc
  NOTE: This patch release is for the T3 Array only and not the
        T3+ Array.  If you have a T3+ Array, and are looking to
        update with the latest patch release, please download
        patch 112276-09. 
        The Sun StorEdge T3 disk tray was formerly known as the 
        Sun StorEdge T300 prior to final product shipment.  Most
        of the Sun StorEdge T3 disk tray user documentation 
        has been updated to reflect the new name;  however, there
        are some related software components (such as the
        Sun StorTools diagnostic package) that still reference this 
        product as the Sun StorEdge T300.  Users should be aware 
        that both the Sun StorEdge T3 and Sun StorEdge T300 names 
        refer to the same product and are equivalent in terms of 
        product features and functionality.
BugId's fixed with this patch:

Changes incorporated in this version:


Patches accumulated and obsoleted by this patch:

110760-02 111175-02

Patches which conflict with this patch: 

Required Patches:

Obsoleted by:
 
Files Included in this Patch: 
T3extender.tar.Z       # script to extends battery life span to 36 months
  disk/                  # T3 disk drive firmware 
  disk/CHANGELISTS       # T3 disk drive firmware release note
  docs/                  # Release Notes, pdf manuals
  ep2_10.bin             # Controller EPROM Flash
  files.tar              # T310 System Files Tar Image
  lpc_05.02              # Unit Interconnect Card Firmware
  patchtoc               # t3.sh: Files to Upload To Target T3 
  previous/              # Recent T3 Firmware Versions
  t3.sh                  # T3 File Upload Utility 
  v1184.bin              # Controller firmware 
README.109115-17       # README file for the patch
Problem Description: 
---------------------------------------------------
109115-17 (1.18.04 Firmware)
---------------------------------------------------
4843539 vol verify in 118.2 does not ask to verify and continue plus no message in log.
4938052 T3A does not report vol verify start and end in syslog like the T3B
4938889 vol verify confuses people by reporting parity mismatch for media error (3/11)
4957659 T3A vol verify run from web interface (storade) does not show in cmdlog or syslog
4957717 T3A vol verify differences when run from web interface vs cli.
4922403 T3 patch readme should include drive fw bug fixes
4974618 T3B/313_2: syslog data prints to console instead of log file
4916219 T3A/T3B: Data miscompare while running test on Pirus boxes with T3A PP
4624156 T3B can cause data corruption during failovers
5038486 T3B/3.1.4.11: data miscompare - 128 words in error (0x0)
4850100 T3A/T3B/6120 READ CAPACITY opcode (0x25) goes through the wrong mpxio path during boot
4970431 "Rush Limbaugh" & "High atop the EIB building" should be removed as defaults
4810817 Backport fix http tokens fails to report standby when 2 vols share standby
 
---------------------------------------------------
109115-16 (1.18.03 Firmware)
---------------------------------------------------
latest disk FW updates
 
 
---------------------------------------------------
109115-15 (1.18.03 Firmware)
---------------------------------------------------
4844948 T3A/T3B/T4:disk management command typo drops master controller in T3
4899498 T3A/T3B/T4: loss of nvram data results in default settings for logto and loglevel
4848907 T3A: syslog"qlcf_i_read_response: Debug Code..." shoud give more explicit logic
4733406 T3 battery errors with "SHELF LIFE EXPIRED" even after PCU replacement
4881214 Wrong size drive inserted into t3 caused u2 controller to fail see 4312061
4808154 Firmware 1.18.1, version string not indicating patch level via http interface
4818207 T3A/B: background reconstruction doesn't report any info about completion 
4869992 Need command to re-enable drive from offline (threshold exceeded) to online
4832135 Bad block correction and predictive drive failing mechanisms are insufficient
4810681 T3B: disk download FW A538 fails t3B 
4836800 Enhance T3 FW to inject 01/5D errors for test purpose
4889551 6120/T3B: syslog (INFO) shows wrong Cmd code when doing LongTransacTask operatio
 
 
---------------------------------------------------
109115-14 (1.18.02 Firmware)
---------------------------------------------------
latest disk FW updates
 
 
---------------------------------------------------
109115-13 (1.18.02 Firmware)
---------------------------------------------------
 
4823585 T3 FW version 1.18.02 keeps generating LIP's
4821006 T3 FW 1.18.02 loglevel does not work correctly
4785593 T3/T4: array may crash after 497 days of uptime.
4729107 upgrade from 1.16 to 1.18 -  after reset -y the logto and loglevel
change
4683597 Typo in schd.conf, causes continuous battery refreshes.
4388177 Need to hardcode Battery Scheduler Refresh Times
 
---------------------------------------------------
109115-12 (1.18.01 Firmware)
---------------------------------------------------
 
4707617 Unrecovered Read errors during 'vol verify fix' operation not corrected
4505867 T3: data miscompare error while running madrw
4648055 Raid 5 'vol disable uxdx to_standby' fails
4664674 Raid 1 'vol disable uxdx to_standby' fails
4675955 Data miscompared in T3 running Madrw with Fujitsu disk drives
4697868 Disk in raid 5 on T3+ failed and Oracle database crashed in clustered
config
 
---------------------------------------------------
109115-11 (1.18.00 Firmware)
---------------------------------------------------
This patch includes updated drive firmware in the disk directory for
ST373405FC Seagate 73GB 10K rpm drive and ST336605FC Seagate 36GB 10K
rpm drive.  This firmware fixes the following bugs:
 
Bug ID 4472275 Fixes errant drive "NOT READY" status while servo is in 
recovery operation.
 
Bug ID 4519031 Fixes merge code problem to prevent performance degradation 
on queued-sequential writes (known as the Slow Vol Init problem).
 
Fixes Marvell register ESD partial-reset condition that causes corruption
of the g-list area and format utility "drive-type unknown" condition.
 
---------------------------------------------------
109115-10 (1.18.00 Firmware)
---------------------------------------------------
 
4457184 1.17 Performance Drop 
4407776 T3 not properly initialize disk paths after disk hot swap
4463349 Change the default setting of the ondg mode from passive to off
4452948 Modified Syslog Messages Get Wrong Serial #
4426801 Return value checking after HostPortFacToLun() call.
4460277 Executing ofdg -y health_check on T3B units causes system to be
unavailable
4519958 Received data exception during bootup and controller reset.
4435227 Cache Should go to write-behind during battery refresh cycle
4432375 lpc/serial communication bug results in ctr hang
4376511 Purple doesnot generate lip when mp_support is changed.
4431121 format entry lingers after removing volume with <drive type unknow>
4455999 Need error handling when can't read midplane
4448563 Reboot/halt active node causes other node to panic w/ Reservation
Conflict
4374724 Multiple Non-Adjacent Disk Failures in a RAID 1 stripe causes LUN to
unmount.
4478381 T3B: Master encounters "Unfixable" file system error on alt. master.
4474779 Purple returns ASC 90 00 for path that is becoming ACTIVE
4480665 disabling a loopcard and then re-enabling the loopcard-loopcards
disables again
4298510 Implementation of SCSI Read and Write Buffer commands.
4410516 cache stays write through even when forcing write behind
4473669 SCSI-3 testsuite causes T3 reset and test failures hait
4474321 TDL/PGR issue can prevent T3 from booting
4474325 commands fail on Purple II
4496053 tail without args resets controller
4411749 too deep a cd leads to instruction access exception and fs messages
4473002 - T3B: 1k data corruption
4488964 silently shut down.
4498487 Firmware reports wrong buffer size for SCSI read/write buffer commands.
4493006 T3 can not clear the key requested by a new PGR command
REGISTER_AND_IGNOREKEY.
4470439 Partner Pair testing with 1.17b fails SCSI-3 Cluster TS reserve_r{1,2}
test
4497511 PGR does not work correctly when connected via a python TL port.
4388855 Change to Controller firmware version format to dot-dot format
4430163 ISP2100 firmware v1.19.108 Target Mode Hang during MPXIO Unit Test
4495720 Purple 1 incorrectly implements EOFni handling
4414235 syslog priority in a T3 can't be changed
4500452 T3 slave controller PGR data base sometimes is not clean.
4383854  Write-behind cache disabled when RAID 5 disk fails
4504356 PGR: T3 needs to take PGR IN/OUT commands on its standby paths.
4483245 u1 hotplug fails to boot
4458768 line break handling is broken
4473389 1.17a Exception reset, warm cache startup code seems to modify cached
data.
4505027 Need to support cross-domain builds
4486603 alternate master reboot while the master pull out
4486451 LUN becomes unavailable while doing DMP test.
4490884 Cache mirror failed after T3 Master ctr disabled (.probe) then enabled
4486568 Disable adjacent drives, followed by replacement and recon = bad data
4480200 Firmware should stop battery discharge at 6 minutes.
4412662 cleanup cmd_1 if cmd_2 cannot be allocated in qlcf_start_gauntlet()
4476044 Correct the residual count and ROR/RUR flags in FCP_STATUS for Inquiry
cmd.
4449891 fix Clear function with cache stats for sys and vol HTTP tokens.
4457439 Bad System Area on disk is not fixed when possible during controller
takeover
4502467 Testsuite misc_r{11} fails --- T3 - for Single brick.
4504882 hist command after long command line can crash system
4407897 1.17-T3B snmp sysDate and sysTime incorrect
4398786 Misleading token/SNMP information if loop card missing
4398788 When disk removed token/SNMP show "fault"
4396005 Misleading token/SNMP information if pcu missing
4351210 less than 256 mb cache detected should be warning not notice
4478907 Disabling of standby drive does not work correctly
4426026 sf2 sf_cmd_callback: Lost Frame (read) received 0x8 expected 0x1f4
target 0x1
4508212 T3WG and HP A5158 HBA locks up HPUX SAM utility
4385004 fw 1.16 long hostname gains copy of root password.
4511648 Prism debugger on purple-1 hit program exception with a break point set
4508802 SCSI r/w buffer cmds should ignore SCSI reservation
4459659 diag syslog messages need controller identification
4506732 Diskomizer stops with data compare error, when run with attenuator
4513285 While doing .probe test, ISP dumps
4434826 Dead T3 -config'ed w/ 2 LUNs, used as quorum panic'ed & killed Cluster
4506206 T3WG sets MultiP bit in standard SCSI inquiry data
4435279 Status for battery "shelf life expired" shows "battery low"
4436728 Data compare error, 2 block fails during Controller pull test
4418601 syslog states Please Send ISPDEBUGDUMP to Development Engineering
4520739 Existence of hidden 'psh' commands, should be removed
4475447 sys stat shows controller booting but role is reported as Altmaster
4521979 sub rev printing problem
4511149 cmdlog - keyboard buffer overflow
4509295 REGISTER operation fails on one initiator
4509300 T3 with PGR reservations active fails under IO load
4386434 Stale FCP port database(Loop Failure)
4524258 P1 and P2 return Success when the host tries to preemptandabort an
unexistent Key.
4497687 sysdiag data compare failure is counted as passed
4509888 Bad drive causes vol verify to hang
4348580 two loop mode causes performance impact
4372821 fru stat now gets all drive temperatures
 
---------------------------------------------------
109115-09 (1.17b Firmware)
---------------------------------------------------
4448563 Halt of active node in cluster causes T3 reservation conflict
 
  (Note: 1.17b contains a single fix required for T3 partner 
         pairs used in Sun Cluster or multi-initiator configurations 
         using SCSI-2 reservations.  Customers using 1.17a firmware 
         in a non cluster/non multi-initiator configuration 
         need not upgrade to this firmware release.  For further 
         details regarding supported Sun Cluster configurations with 
         T3, please refer to the corresponding Sun Cluster product
         documentation as well as the 1.17b release notes (available 
         in this patch).
 
---------------------------------------------------
109115-08 (1.17a Firmware + Patch Respin)
---------------------------------------------------
 Functionally equivalent to -07 release with the inclusion of previously 
 released 1.16a and 1.16c firmware versions.
 
---------------------------------------------------
109115-07 (1.17a Firmware)
---------------------------------------------------
 Note: This firmware release superceeds all previous T3 firmware
       releases.  Full support for SunCluster single brick 
       configurations (formerly only supported with 1.16a 
       firmware) are supported with this release.  See the
       1.17a release notes included in this patch for further
       details.
 
4286243 Need active channel bit from T300
4302763 Controller Temperature token data incorrect
4303429 Token for Volume WWN appears incorrect
4306672 failover issue with multi-initiator configuration
4342154 Assertion reset with DMP and expansion units
4354565 Queue full messages received for less than 64 in-transit IOs
4356418 Cybercop test causes controller data access exception
4365734 Power supply status from HTTP server doesn't match actual state 
4366223 Some failed disk errors can start graceful system shutdown
4367372 fru stat reports ready for disk ports when loop cards are missing
4367622 boot -i w/telnet can hang due to lack of memory
4369314 http token problem if ctr status is "absent" or "disabled"
4372831 Cache mirroring needs to sync with volume recreation
4373406 Need ability to bind a host WWN to the initiator ID.
4373801 SNMP: mib out of sync with http tokens
4374059 SNMP: MIB Description Fields Are Out Of Date
4374280 Slow Failover w/ RAID 0 and VxVM Host Based Mirroring
4376303 IPI-3 to SCSI mapping incorrect causing Invalid Command Results
4377075 Offline host sometimes not detected 
4377097 instruction access exception from t3 ftpd
4377279 Request Sense CDB should get Unit Attention Info in a Data Frame
4377484 Removing hot spare w/ one bad RAID 1 drive, offlines LUN
4377795 w/u2 as master pulling FC cables in DMP test causes probe break
4379816 Fan status doesn't update after fan fault and fru replacement
4381510 New ELF code causes ctr disable to not cause a failover
4382859 Attempting to disable a ctr using the CLI disable u1 fails
4384970 httpd gets an exception reset on long filenames
4385877 Request Sense CDB should get sense data returned in data fram
4386836 Drive firmware download can hang
4391664 Need to force T3 to be always be a PLDA private loop device
4393080 Port listmap is not updated properly after reboot
4394863 enabling a controller can take up to 16 minutes.
4397959 Extreme system load test can cause 128 byte shift
4398347 Host loses T3 paths when isp2100 chip reset was performed
4402518 disk replacement results in invalid system area
4403519 Uninitialized variable cleanup
4405603 internal disk utility changes needed for IBM disk support
4406749 Lun reconstruction can be slow with light IO from host
4406960 SCSI-3 Testsuite: tc_mhiocgrp_reserve{2} failed
4406971 SCSI-3 Testsuite: /tests_reboot/tc_misc/tc_misc{5} failed.
4406977 SCSI-3 Testsuite: /tests_reboot/tc_misc/tc_misc{11} failed.
4411125 Fatal drive timeouts w/Seagate Cheetah 4 disks causes slow I/O 
4413938 boot -i command sometimes does not return
4414569 Excessive controller failovers can cause file system issues
4416530 "refresh -s" command shows inconsistent refresh date values
4419265 Alt master disables
4419795 Data miscompare results from bad ISP response 
4420494 Halt on Alternate controller can cause system halt on master
4421372 New 1.17 PGR3 feature causes data consistency issue
4421398 Detected bad accumulator should stop boot cycle
4422437 Need to expand variables used to monitor luns during failover
4426777 Monitoring code needed to detect slowly degrading drives 
4426848 System reboot in reconstruction can make the system unavailable
4427539 Accumulator Failures during POST don't get logged
4428961 w/host multi-pathing, INACTIVE to ACTIVE state changes cause hangs
4429293 Too Many "Lun is becoming active" syslog messages with mpxio
4429474 Battery syslog to provide better refresh cycle messaging 
4429265 Battery scheduler file needs to revert to 28 days
4429830 tzset/date change during battery refresh causes false hold time
4431187 vol mode doesn't change to writebehind when cache/mirror=auto
4431302 local ftp client connection issues
4431621 Bad detected disks should be fenced off 
4431999 Vicom Router (Tachyon) and T3 (Qlogic) incompatibility
4432631 Reconstruction does not start simultaneously with mp_support=rw
4434141 Default Value for ondg 1.17 must be 'passive'
4448563 Reboot/halt active node reservation conflict
4455315 Firmware 1.17a shows up incorrectly in ver output
 
---------------------------------------------------
109115-06 (1.16c Firmware) + Drive Firmware Update
---------------------------------------------------
  Seagate Cheetah 4 Drive Firmware Update
 
---------------------------------
109115-05 (1.16c Firmware)
---------------------------------
  4419265: altmaster disables in production test
  4403519: Uninitialized variables being used
 
 NOTE: This patch firmware release (1.16c) does not include changes 
       made in 1.16a.  For SunCluster 2.2 support, please continue to
       use patch 110760-01. The issues resolved in 1.16c only occur
       with partner pair configurations.  As SunCluster 2.2 is currently 
       supported with single T3 tray configurations (WG) only, the fixes       
 
       contained in 1.16c are not relevant. In future patch releases, 
       the fixes in patch 110760-01 will be integrated with patch 109115.
 
 
---------------------------------
109115-04 (1.16 Firmware)
---------------------------------
  4345011 Failed disk drive can caused partner group to go offline
  4345036 Assert Reset (3000):qlcf.c line 3289 Assert(ccb->cam_ccb_list
  4363630 Probe break in qlcf.c due to unexpected ISP chip status
  4337653 Enabling a disabled controller through CM sometimes fails
  4348500 panic on cluster master results in reservation conflict on T3
  4353469 battery refresh stuck in a discharge loop
  4361866 during drive hot plug test , dex io errors and probe break
  4296017 cache stays at writethrough after controller/loopcard failover
  4339555 ofdg run with a bad u2l1 causes T300 reboot loop
  4341193 Upgrade/Downgrade lpc fr/to 4.13 & 5.01 caused amber LED
  4342142 EU: Multiple drives bypassed when using .probe in fail-over t
  4346447 Tokens don't provide accurate status after a ctr enable 
  4350267 Disk is being bypassed during volume initialization
  4353101 rack configuration fails FC cable to hub failure test
  4353660 MADRW errors because T3 is busy handling drive disable
  4353667 Interrupted more command results in performance loss
  4353731 Incorrect value in LPC 5.01 fw download disables T3
  4359814 Multi drive hot plugs cause ISP chip dumping data
  4363780 Target Reset Not Issued To Clear Reservations
  4322151 Missing controller doesn't start overtemp shutdown timer
  4338553 Incorrect display of lpc SN's in fru list 
  4351027 tftpboot of nb113.bin on systems w/new drives drops to ADMIN
  4352277 Battery refresh does not properly maintain interval specified
  4371858 README.109115-03 states t3.sh prompts with T3 login prompt
  4371912 README.109115-03 identifies wrong ftp step 
  4371926 README.109115-03 does not identify how to determine disk drive type
  4371933 README.109115-03 should tell user to remount volumes 
  4383266 t3.sh script fails if executed from directory other than "."
 
---------------------------------
109115-03 (1.14 Firmware + Disk Drive Firmware)
---------------------------------
  T3 Disk Drive Firmware included in patch.
 
---------------------------------
109115-02 (1.14 Firmware)
---------------------------------
  4344316 Stray IOCB's cause probe break
  4350265 Back-end cache mirroring enable problem
  4346571 EU: Probe break on controller exhausted mbox commands 
  4326248 t3.sh patch installation script overwrites .netrc 
  4290158 Reconstruction doesn't start after boot with a failed disk
  4304266 No drive reconstruct if drive fails when volume is unmounted
  4306056 More robust DRAM parity error reporting/handling
  4302850 Cluster: rsv100.bin fails scsi2 reservation test suite 
  4309906 volume create/delete/mount/unmount POST operation returns early
  4309901 CM unable to detect or notify failed volume initializations 
  4311688 Drives are offlined when unmount and recreate a LUN with one lun 
  4317086 Separating a partner group will cause single unit boot cycle
  4306345 sysAutoDisable token doesn't give enough info about autodisable 
  4292138 System needs manual loop failure isolation facility
  4326147 multi-controller disable during heavy load/stress test
  4280101 ISP2100 f/w panic during PCI/DMA errors 
  4305281 T3 trying to use AL_PA 0x01, can cause config problems 
  4262121 Need http token for ondg output
  4290161 Excessive LIPs can cause SCSI 'Report Lun' issues
  4290677 ISP2100:Outgoing Mailbox 0 register reports 0x8002 (sys err)
  4293211 T3 should immediately execute scsi "report lun" & inquiry 
  4293252 Qlogic firmware LIP'ing prematurely 
  4297464 Master Controller disable during drive hot plug simulation 
  4311922 T3 syslog date stamp often off by timezone offset
  4313092 Controller failover test needs a second reseat to boot
  4317148 elemprop.htm page shows wrong values for fruPowerBatLife 
  4326190 Miscellaneous sys command changes
  4326920 running ofdg 'health_check' with u1l1 disabled resets T3 
  4282275 Some system default settings need to be removed 
  4291723 Fan failure injection Doesn't Correctly Initiate LED
  4307139 Some syslog entries to be moved from warning to notice
  4308583 Back-end loop failure test causes stale FC-AL port
  4317596 Copyright login banner should be updated
  4335062 Loop 1 split should not be allowed in Non-HPC enviroments
  4323931 SGI:T3 locks up in a hang status until SYNC cmd issue
  4329797 http traffic during ofdg -y fast_find causes probe break
  4331699 T3 with one lun can Qfull and stop all i/o for 60 seconds
  4335848 Drives being spun down by controller firmware
  4329876 infinite loop after restart from TDL probe break
  4331817 token for controller temperature should be celsius
  4260918 A bad interconnect cable causes repeated LIPs
  4299474 T3 POST should be able to detect cache memory parity errors
  4325782 Intercept all exception vectors for CPU
  4331682 OFDG Abort tokens should be removed
  4332462 Probe break after reset -y, following boot -i file 
  4335250 Drive component failure caused probe break during ofdg run
  4323937 Reservation not cleared with SCSI Reset
  4335070 CM2.1 after "Disable" of u2ctr, "Disable" goes inactive
  4324402 CM showed wrong loop card as disabled
  4332909 Upgrade from 0.95 to 1.00 results in probe break
  4333385 Excessive characters to passwd command causes probe break
  4333439 File system check got a verify volume failure
  4333611 Double disk pull (w/standby) on RAID 1/5 causes boot loop
  4334609 fru stat loop cable display is reversed
  4328814 battery/pcu LED should go amber on battery hold test failures
  4335870 New HPC Vendor ID breaks T3 back-end cache mirroring 
  4336121 firmware shuts off all token access during OFDG tests
  4334945 ONDG error token indicates prematurely testing is complete
  4336123 CM2.0 and T3 FW1.11 result in number format exception
  4336487 Loop card firmware 5.01 doesn't show the vendor/model fields
  4333578 Progress indicator does not work for OFDG
  4311701 OEM:With cache mirroring enabled need to support write caching
  4317995 T3 volumes got unmounted during heavy load/stress
  4330350 ofdg uses inconsistent loop card device names
  4332202 When in writebehind cache mode, enabling failed controller fails
  4334419 Battery Scheduler File To Be Moved to 14 Days
  4328000 sys command option 'vendor' is available through useage 
  4338106 OFDG diag status never updates to show it completed
  4337620 Controller Firmware Should reset hung Qlogic Chips
  4342258 Patch readme to install firmware incorrect
 
--------------------------------------
109115-01 
--------------------------------------
  (1.01a RR Firmware Release)
 
 
Patch Pre-Install Instruction:
------------------------------
 
  1) ftp the 'syslog' or the file to which the system log is directed
     from required T3A on which patch 109115-17 is planned to be installed.
 
  2) Keep this 'syslog' file in a local directory  on host system and run
     following  command.
 
     egrep -i '0x5D|Threshold|0x15|0x4|Mechanical|Positioning|Exceeded|Disk Error' syslog
 
      If you see any of following error messages then take appropriate action
      of backing up of data from the volume, replace the drive reporting any of
      these errors, ensure the volume is in optimal working state without any
      drives disabled and then Install the patch.
 
     An Example:
 
     Here 'u2d5' and  'u1d3' shows the location of drives.
 
     test_host% egrep -i '0x5D|Threshold|0x15|0x4|Mechanical|Positioning|Exceeded|Disk Error' syslog
 
        Jun 05 06:16:14 ISR1[2]: W: u2d5 SCSI Disk Error Occurred (path = 0x0)
        Jun 05 06:16:14 ISR1[2]: W: Sense Key = 0x4, Asc = 0x15, Ascq = 0x1
        Jun 05 06:16:14 ISR1[2]: W: Sense Data Description = Mechanical Positioning Error
        Jul 31 16:19:22 ISR1[1]: N: u1d3 SCSI Disk Error Occurred (path = 0x1)
        Jul 31 16:19:22 ISR1[1]: N: Sense Key = 0x1, Asc = 0x5d, Ascq = 0x0
        Jul 31 16:19:22 ISR1[1]: N: Sense Data Description = Failure Prediction Threshold Exceeded
Revision History: 

109115-04 109115-16 110760-02 109115-07 109115-11 109115-15 109115-03 109115-10 109115-08 109115-14 109115-13 109115-06 109115-09 111175-02 109115-02 109115-01 109115-05 109115-12

Patch Installation Instructions: 
-------------------------------- 
 
 This patch includes a firmware uploading utility (t3.sh) that 
 simplifies transferring the contents of this patch to a StorEdge
 T3 system.   This script is intended for use on Solaris host 
 systems only.  To manually install the contents of this patch
 see the pertinent section below.
 
 *** Warning *** Warning *** Warning *** Warning *** Warning ***
 BEFORE attempting to load firmware on a StorEdge T3 system, be sure to
 stop all IO activity from all attached host systems.  This procedure
 requires a T3 system reboot so all necessary host preparations
 needed to sustain this procedure should be made before starting.
 It is recommended all T3 volumes be unmounted on Solaris before 
 proceeding with this patch installation.
 
 Note: To verify the current firmware version running on a target
       T3 system, use the 'ver' command at the T3 command line
       as follows:
 
         t3:/:<3>ver
 
         T300 Release 1.14 2000/07/12 19:22:50 (192.168.209.123)
         Copyright (C) 1997-2000 Sun Microsystems, Inc.
         All Rights Reserved.
 
  To update the T3 system with the entire contents of this patch follow
  the steps below after quiescing IOs from the host: 
 
 1. System Preparation
    Once the patch has been downloaded to a Solaris host, extract 
    (if necessary) the contents of the patch to a temporary working 
    directory.  
 
 2. Verify the T3 system to be upgraded is reachable on the network:
 
         $ ping t3
           t3 is alive
 
 3. Verify the T3 system has a root password (the 't3.sh' patch utility 
    uses ftp to transfer the files to the T3 which requires a root 
    password):
 
        $ telnet t3
        Trying 129.150.47.115...
        Connected to t3.
        Escape character is '^]'.
 
 
        pSOSystem (129.150.47.115)
 
        Login: root
        Password:       <---- Must type password here
 
 
        T300 Release 1.14 2000/07/12 19:22:50 (192.168.209.123)
        Copyright (C) 1997-2000 Sun Microsystems, Inc.
        All Rights Reserved.
 
        t3:/:<1>
 
   If no root password is set on the system, be sure to set one by logging 
   into the T3 system and using the 'passwd' command.
 
 4. Transfer patch contents to T3 system.
 
    Note: There is limited space available in the T3's reserved system 
          area.  Therefore, it is important to be sure there is 
          adequate space on the T3 before proceeding with the 
          procedure to ftp firmware images to the unit.  It is
          not necessary to keep old images of controller firmware, 
          unit interconnect card firmware, or eprom binaries 
          on the T3 once those images have been loaded per the
          instructions provided in this readme.
 
    The recommended way to install the contents of this patch on 
    T3 systems is to use the included t3.sh script from a Solaris
    host that has network access to the target T3 system being 
    upgraded.  This utility will transfer the required files in this patch 
    to the target system depositing the files in the correct directories.  
    If a Solaris host isn't available, the contents of this patch 
    can be manually uploaded to the target T3 system using the following
    method.  
 
    Note: It is not necessary to transfer all files contained in this patch
          to a target T3 system.  For example, the docs subdirectory in
          the patch provides reference documentation and is not required
          by a T3 system.
 
      Manual File Installation
      ------------------------
 
      -> Extract the contents of the 'files.tar' image to a 
         temporary working directory:
 
      -> Manually ftp the following files contained in this patch  
         to the corresponding directory on the T3 system:
 
             Patch Source Location        T3 Destination 
             -------------------------    ------------------------
              ./ep2_10.bin                 /ep2_10.bin
              ./lpc_05.02                  /lpc_05.02
              ./v1184.bin                  /v1184.bin  
 
           (From temporary Working Directory)
              ./etc/schd.conf              /etc/schd.conf
              ./web/*.htm                  /web
              ./web/snmp/t300.mib          /web/snmp/t300.mib
 
    Automated File Installation
    ---------------------------
    Note: The 't3.sh' installs all controller and system files but 
          does not overwrite /etc/hosts and /etc/syslog.conf files 
          on the target T3 system as these files are typically
          customized per local operating environment requirements.  
          One exception to this is the battery refresh scheduler
          file on the T3 (/etc/schd.conf).  The t3.sh script
          will make a backup copy of this file on the T3 (to 
          /etc/sch_old.conf) before copying over the new 
          /etc/schd.conf file.  Factory default versions of these 
          files do exist in the accompanying files.tar image in 
          this patch, should they be required however.
 
    To start the installation script, first verify the target T3 
    system can be reached through the local network (use ping to verify 
    the target T3 system is reachable).  Once this has been confirmed,
    the installation script can be started as follows:
 
       ./t3.sh
 
    (Note: Be sure the t3.sh script is executable.) 
 
    The t3.sh utility will prompt for information as follows:
 
      Please Enter Hostname or IP Address Of T3 To Be Ugpraded: 
 
       -> Enter Hostname or IP address of the target T3
          system.
 
    Please Enter Patch Location Pathname [.]: 
 
       -> Enter path to where the files.tar image exists.  Typically
          the default current working directory is sufficient 
          (hitting enter will accept the current working directory).
 
    Please Enter Your Home Directory Path [/home/joe_user]:
 
       ->  The home directory of the user ID used when launching the 
           t3.sh script (this is used by ftp to automatically load the patch
           file contents to the T3).
 
    At this point, the automatic ftp login/upload process should
    begin.  The user will be prompted with a ftp login prompt at
    which point the user should respond using the default T3 root 
    login and password.
 
 5. Load new Unit Interconnect Card Firmware:
    Using 'lpc version' on the T3, if the loop card firmware is 
    running downrev firmware, upgrade all loop cards in the partner 
    group as follows from the T3 command line:
 
        :/:<1>lpc version
                        LOOP A          LOOP B
        Enclosure  1    5.01 Flash      5.01 Flash     
        Enclosure  2    5.01 Flash      5.01 Flash     
 
        :/:<2>lpc download u1l1 lpc_05.02
 
    Repeat the above steps for all units in the partner group (ie u2l1 
    and u2l2).
 
        :/:<3>lpc download u1l2 lpc_05.02 
        :/:<4>lpc download u2l1 lpc_05.02
        :/:<5>lpc download u2l2 lpc_05.02
 
 
      Note: It is possible to string t3 commands together using the 
            semicolon command.  This allows a single command line session
            to launch several commands without waiting for each command
            to complete.  To upgrade both loop cards one controller
            for example, one could type the following:
 
            :/:<2>lpc download u1l1 lpc_05.02; lpc download u1l2 lpc_05.02
 
    From the command line, verify the correct unit interconnect card 
    versions are loaded as follows:
 
        :/:<6>lpc version
                        LOOP A          LOOP B
        Enclosure  1    5.02 Flash      5.02 Flash     
        Enclosure  2    5.02 Flash      5.02 Flash     
 
 
 6. Boot the T3 controller boot code.
 
    From the T3 command line, type the following to install the
    boot code:  
 
       :/:<7>boot -i v1184.bin
       file header: size 274ad4, checksum 57345395, start 20010, base 20000 
 
 
   (Caution: be sure all IOs have been quiesced and no host IO activity
             is scheduled to start until the upgrade procedure has completed)
 
 7. Verify And Download New EPROM Code If Necessary.
    Note: This step can be skipped if the controller revision string 
          displayed by the 'fru list' command matches the EPROM binary 
          image included in this patch.  The following example
          shows 'fru list' output for a controller running 2.10 level
          EPROM code which matches an 'ep2_10.bin' EPROM binary:
 
      :/:<10>fru list u1c1
      ID      TYPE               VENDOR    MODEL        REVISION     SERIAL
      ------  -----------------  --------  -----------  ----------   ------
      u1ctr   controller card    SCI-SJ    375-0084-01- 0210/011803  000689
 
    To download new EPROM code, from the T3 command line, type the 
    following:
 
       :/:<8>ep download ep2_10.bin
       Done with writing EPROM code of controller 1
       Start writing EPROM code of controller 2
       Done with writing EPROM code of controller 2
 
 8. Verify system boot mode set to auto:
    From the T3 command line, type the following:
 
       :/:<9>set bootmode auto
 
 9. Reset the T3 System as follows:
 
       :/:<10>reset 
       Reset the system, are you sure? [N]: y
 
10. Once the system has booted successfully, log into the system and 
    verify the boot code is properly loaded using the 'ver' command
    as outlined earlier.  Output should be similar to the following:
 
     T300 Release 1.18.02 2003/02/28 11:30:28 (10.4.57.53)
     Copyright (C) 1997-2001 Sun Microsystems, Inc.
     All Rights Reserved.
 
 
11. type "port list" and verify ports
 
      :/:<1>port list
 
      port   targetid   addr_type   status   host   wwn
      u1p1      1        hard       online   sun    50020f2300000f61
      u2p1      2        hard       online   sun    50020f230000297d
 
12. Verify volumes are visible and mounted.
 
    From the command line, enter the following:
 
      :/:<2>vol list
      volume        capacity   raid   data     standby
      v0             71.6 GB    1     u1d1-8    u1d9
 
13. Congratulations, the upgraded T3 is ready to use again.
 
Drive Firmware Upgrade Instructions
------------------------------------
Note: A disk drive firmware upgrade may not be necessary.  To 
      verify the most up to date drive firmware versions are installed,
      run the 'fru list' command on the StorEdge T3 system and
      compare the results of that output with the information 
      found in the README.disk file (see the disk subdirectory of this 
      patch).
 
During a disk drive firmware download, the functionality of the disk
tray is limited.  To avoid system problems verify:
 
  o A current backup copy of the data on the T3 exists.
 
  o The data path between the T3 and the host has been quiesced.  
    There must not be any IO activity during the disk drive firmware 
    download.
 
  o The ethernet connection to the T3 is not being used for any other
    operation during this procedure.  If Component Manager is being
    used to monitor the T3, automatic polling must be disabled. 
    Refer to the Component Manager Users Guide for instructions to
    disable T3 polling.
 
  o No unnecessary command line program interaction with the T3 system 
    is performed during disk drive firmware downloads.
 
  Note: The disk firmware download will take approximately 20 mins for 
        9 drives.  Do not attempt to interrupt the download or perform 
        other command line functions during the process.  The command 
        prompt will return after the download process has completed.
 
Disk Firmware Upgrade Instructions
------------------------------------
1. Using ftp, transfer the appropriate disk drive firmware to the 
   T3 root directory from the disk/ subdirectory contained in this
   patch.  Be sure the file is transferred in binary mode.  
 
     Note:  The T3 system limits the filename length of files being 
            transferred to the local disks.  Be sure the file name 
            is 12 characters or less in size and that the file name 
            starts with an alphabetic character (not a numeric). It is 
            recommended the file names provided in the disk/ subdirectory
            not be changed.
 
2. Establish a telnet connection with the T3 (see T3 product
   documentation for specific details if necessary).  Log into
   the system as 'root'.
 
3. Verify all T3 disks are in an optimal state as follows:
 
     -> Confirm all disks are ready and enabled using the T3 'fru stat' 
        command. 
 
     -> Confirm all disks configured into volumes are in an optimal
        state using the 'vol stat' command.  All drives should report
        a drive state of zero.
 
     If there are drive issues reported, correct these problems before
     proceeding with the disk drive firmware download procedure.
 
4. Verify no volume operations are in progress using the 'proc list'
   command.  If a volume operation is in progress, this operation 
   must be allowed to complete before proceeding.
 
5. Verify no battery refresh operations are in progress using the
   'refresh -s' command.  If a battery refresh is in progress, it
   is recommended the refresh operation be allowed to complete 
   before proceeding with disk drive firmware downloads.
 
6. Unmount T3 volumes
 
   To ensure no host IOs are active, unmount all T3 volumes from 
   the host system.  In addition, it is recommended the internal T3 
   volumes be unmounted as follows (using volume v0 as an example)
 
      :/:<1>vol unmount v0
 
7. Install the drive firmware using the T3 'disk download' command
   as follows (this example assumes a download is being performed
   on drives on a master tray.  Substitute FILENAME with the file name
   of the actual disk drive firmware image ftp'd to the tray in step 1):
 
     :/:<2>disk download u1d1-9 FILENAME
 
 
   Note: -> In a partner group, the disk download command can only
            specify one set of 9 drives at a time.
         -> All drive types specified on the command line *must* 
            be of the same drive type.  If individual drives 
            require different firmware versions, multiple invocations
            of the 'disk download' command must be used to download
            firmware.
         -> If the wrong firmware type is specified for a given drive,
            the disk drive will reject the erroneous file download 
            request and revert back to the disk firmware that was running
            at the time of the download request.
         -> It is possible to invoke multiple calls to the download
            utility by separating the commands with a semicolon 
            as in the following example:
 
          disk download u1d1-9 FILENAME; disk download u2d1-9 FILENAME
 
8. Verify the drive firmware download was successful using the T3
   command 'fru list'.
 
9. Reboot the Sun StorEdge T3 array after all drives have been upgraded.
   The T3 system can be rebooted using the T3 'reset' command.
 
     Note: In some cases after a drive firmware download, older firmware
           version strings may still display in the 'fru list' command.
           A reset of the T3 after the download ensures the version 
           information is updated correctly in internal T3 tables.
 
10. Once the tray has come back online, log into the array and verify
    optimal FRU states by doing the following:
 
     -> Confirm all disks are ready and enabled using the T3 'fru stat'
        command.
 
     -> Confirm all disks correctly report model number and new 
        firmware version information correctly using the T3 
        'fru list' command.
 
     -> Confirm all disks configured into volumes are in an optimal
        state using the 'vol stat' command.  All drives configured
        in volumes should report a drive state of zero.
 
11. Remount the unmounted volumes using the T3 'vol mount' command.
    In addition, on all attached host systems, remount any T3 volumes
    that were unmounted in step 6.
 
 
---------------
  Appendix A
---------------
 
The following sections describe major functionality changes in this 1.18.03
firmware level.
 
 
   ----------------------------------------------------------------
1. Predictive Failure Error (or SCSI code 1/5d/xx) Handling Changes
   ----------------------------------------------------------------
 
    When a disk reaches its error threshold, it will report
    a SCSI error 1/5d/xx to the T3 controller, the T3 syslog will
    contain the following messages for the disk, by using u1d4 as
    an example:
 
        Aug 06 15:22:06 ISR1[1]: N: u1d4 SCSI Disk Error Occurred (path = 0x0)
        Aug 06 15:22:06 ISR1[1]: N: Sense Key = 0x1, Asc = 0x5d, Ascq = 0xff
        Aug 06 15:22:06 ISR1[1]: N: Sense Data Description = Failure Prediction Threshold Exceeded (FALSE)
        Aug 06 15:22:06 ISR1[1]: N: u1d4 SVD_CHECK_ERROR: prediction err: 01/5D
 
    When the T3 controller receives this error, if there is a spare
    disk assigned to the volume where the disk belongs to, and if
    the volume/slice is a RAID 1 or 5, T3 will automatically start
    a background volume reconstruction of the failing disk to the
    spare disk.  The T3 syslog will show messages like:
 
        Aug 06 15:22:06 ISR1[1]: W: u1d4 disk will fail soon.
        Aug 06 15:22:06 ISR1[1]: N: u1d4 vol recon is going to start if autorecon is on.
        Aug 06 15:22:06 ISR1[1]: N: u1d4 please replace this disk after it has been subst'd.
 
        Note: "autorecon" is an internal default setting and it should
              be set to "on" in all cases.
 
      When the volume reconstruction starts, the following message
      will be recorded in the T3 syslog:
 
        Aug 06 15:22:11 LT00[1]: N: u1d4 Copy drive to standby disk started
 
      When the volume reconstruction ends, the following message will
      be recorded in the T3 syslog file:
 
        Aug 08 00:03:27 LT00[1]: N: u1d4 Copy drive to standby drive completed
 
      When this reconstruction process ends successfully, the failing
      disk will be marked as "substituted" and user can replace it.
 
    If the LUN is not RAID 1 or 5, or if no spare disk is available for
    RAID 1 or 5 LUN, or if the reconstruction fails, no action will be
    taken by T3, and the reporting disk will be left "operational" as it is.
 
   ---------------------------------------------
2. Disk firmware download functionality changes. 
   ---------------------------------------------
 
   Disk firmware download process is made more robust. The user interface and
   functionality remains same except for following case.
 
   When multiple disk firmware download command is issued,
 
   Example: disk download u1d1-9 'firmware_file'
 
    If one of the disks in the range fails,  the disk download operation terminates
  immediately and does not attempt to download firmware on remaining disks. This is
  done to avoid multiple disk failures.
 
 
---------------
  Appendix B
---------------
 
The following section describes useful tips.
 
   ----------------------------------------------------------------
1. How to start and stop automatic device monitoring under StorADE.
   ----------------------------------------------------------------
 
   Using the 'ras_admin' command, one can stop and start the StorADE cron
   job that monitors all devices.
 
      The command syntax is:
 
        /opt/SUNWstade/bin/ras_admin stop/start_cron
 
 
   Also, using the 'ras_admin' command, one can view the polling activity
   status of each devices defined in StorADE.
 
      The command syntax is:
 
        /opt/SUNWstade/bin/ras_admin device_list
 
 
      The output of this command contains a column labeled 'Active', with
      'Y' denoting active monitoring and 'N' for in-active monitoring.
 
   For more details about StorADE, please refer to the StorADE User's
   Guide documentation.
 
 
---------------
  Appendix C
---------------
 
About T3extender.tar.Z
 
T3 units were originally designed with a battery expiration/
obsolescence strategy to protect customers data integrity in the event
of battery failure.
 
Historical and installed base data has established that the original 24
month battery expiration did not provide an adequate service life for
the battery/PCU units.  The result was unnecessary replacement of PCU's
and batteries.  This premature replacement increased outage
opportunities that could be caused by inadvertent damage to other
internal parts and/or reinitializing the unit during battery/PCU
replacements.
 
A file T3extender.tar.Z is included with this T3 patch.
T3extender.tar.Z contain a simple perl script that extends the battery life 
span from 24 to 36 (1095 Days 18 Hours) months via their Ethernet connection. 
 
To install and execute the program, perform the following steps:
1. # zcat T3extender.tar.Z | tar xf -
2. # cd T3extender
 
There are four files that under the T3extender directory, which are 
I.   batxtender -- script that extends the battery life span.
II.  perlx      -- perl library
III. t3hosts.example -- syntax example of editing the t3hosts file
IV.  README -- detailed procedure on how to run the script, please 
               read this before you run the script
 
3. (optional) edit the t3hosts file (see t3hosts.example)
4. # ./batxtender
Special Install Instructions: 
-------------------------------------------
If you plan to run several automated file installation scripts (t3.sh)
the same time on one host to update many T3A systems, you must enter
different "Home Directory Path" since t3.sh script will use $HOME/.netrc
for ftp. Please make sure that you have full permission in those
directories.

README -- Last modified date:  Thursday, March 9, 2006

 
 
Login Required

You must login and have a valid contract to access Sun's Premium content which includes:

  • Sun Alerts
  • Bugs
  • Patches
  • Solutions
  • White Papers
  • Documentation
  • Support Knowledge

Login Required

You must login and have a valid contract to access Sun's contracted features

Access Legend:

(Login to access)   Sun Contracted Content
(Login to access)   Sun Contracted Feature

Please make use of SunSolve Feedback application by selecting the floating [+] to provide feedback about this specific document.

Search

Article Details
Article ID : 109115-17
Article Type : Patch Descriptions
Last reviewed : 2006-03-09
Audience : PUBLIC
Keywords : t3 t300 t310 raid storage firmware loopcard eprom interconnect
Provide feedback  (help)
Page Tools
»  Print This Page
»  Email This Article
»  Bookmark This Article
 
Contact About Sun News & Events Employment Site Map Privacy Terms of Use Trademarks Copyright Sun Microsystems, Inc. | SunSolve Version 7.4.0 #1