73.4GB 10K RPM
Fujitsu MAW3073FC, 73.4GB - 10000 RPM FC Disk Drive
Hitachi HUS1073FA, 73.4GB - 10000 RPM FC Disk Drive
Seagate ST373207FC, 73.4GB - 10000 RPM FC Disk Drive
73.4GB 15K RPM
Seagate ST373454FC, 73.4GB - 15000 RPM FC Disk Drive
Hitachi, 73.4GB - 15000 RPM FC Disk Drive
146.8GB 10K RPM
Fujitsu MAW3147FC, 146.8GB - 10000 RPM FC Disk Drive
Hitachi HUS1014FA, 146.8GB - 10000 RPM FC Disk Drive
Seagate ST3146707FC, 146.8GB - 10000 RPM FC Disk Drive
146.8GB 15K RPM
Seagate ST3146854FC, 146.8GB - 15000 RPM FC Disk Drive
Fujitsu, 146.8GB - 15000 RPM FC Disk Drive
300GB 10K RPM
Fujitsu MAW3300FC, 300GB - 10000 RPM FC Disk Drive
Seagate ST3300007FC, 300GB - 10000 RPM FC Disk Drive
Note 1: All RAID configurations ship pre-configured with RAID level zero (RAID 0).
Note 2: Supported RAID levels include 0, 1, 0+1, 1+0, 3, 5, 3+0, and 5+0.
Up to 12 Disk drives per array
73.4GB Disk drives
12 x 73.4 = 880.8GB
146.8GB Disk drives
12 x 146.8 = 1.762TB
300GB Disk drives
12 x 300 = 3.6TB
Power Requirement
AC: 90 to 132 VAC, 180 to 264 VAC (47 to 63 Hz)
DC: -36 to -75 VDC
Input Voltage
AC: 100 to 240 VAC, single phase
DC: -48 to -60 VDC, 18A
Current Per Input
AC: 100 to 240 VAC, 50 to 60 Hz, 5.0-7.1 A
DC: -48 or -60 VDC, 18A
Heat Output
785 BTU/hr (fully populated array, max)
Altitude
Operating: -30 m to 3,048 m(-100 to 10000 feet)
Non-operating: -30 m to 12192 m(-100 to 40000 feet)
Temperature
Operating: 5° C to 40° C (41° F to 104° F)
Non-operating: -40° C to 65° C (-40° F to 149° F)
Humidity
Operating: 10% to 90% relative to 27° C max.
wet bulb, noncondensing
Non-operating: 93% relative to 38° C max. wet bulb, noncondensing
Shock
Operating: 5.0 G, 11-ms, half-sine
Non-operating: 15.0 G, 11-ms, half-sine
Vibration
Operating: 0.2 G, 5-500 Hz, swept-sine
Non-operating: 1.0 G, 5-500 Hz, swept-sine
Height
Desktop: 9.25 cm (3.64 in)
Rackmount: 8.89 cm (3.5 in)
Width
Desktop: 48.26 cm (19 in)
Rackmount: 44.7 cm (17.6 in)
Depth
Main Chassis with bezel: 48.36 cm (19.04 in)
Chassis with Power/Fan Modules and bezel: 53.44 cm (21.04 in)
Chassis with Power/Fan Modules, Handles and bezel: 55.98 cm (22.04 in)
Weight (with 12 disks)
Desktop: 31.43 kg (69.3 lbs)
Rackmount: 28.71 kg (63.3 lbs)
RoHS Compliance Level
RoHS:YL
Safety
UL listed UL 60950:2000, CSA-C22.2 No. 60950-00, EN
60950:2000, IEC 60950, TUV, CB Scheme, GOST-R Mark; S-Mark, FCC Part 15
Class B, CISPR 22 55022:1998 Class B, ICES-003
Emission
VCCI Class B, EN AS/NZS 3548:1996, BSMI CNS 13438 Class
B, S Mark
Harmonics
IEC 61000-3-2:2000, IEC1000-3-3:1995/A1:2001
Immunity
CSIPR 24 EN 55024
Other
NEBS Level 3 (GR-63-CORE; GR-1089-CORE), MIL-STD-810F,
ETSI EN 300 386
Front
37 cm (15 in) service clearance, 15 cm (6 in) cooling
clearance
Rear
37 cm (15 in) service clearance, 15 cm (6 in) cooling
clearance
Airflow for cooling is from front to rear
Rack mountable in 19" wide rack