Sun Blade 1000 - Hardware Specifications

Sun Blade[tm] 1000 Workstation: Hardware Specifications

Processor
Number Up to two
Architecture 600-, 750-, 900-MHz UltraSPARC[tm] III, or 900-MHz UltraSPARC III Cu
Cache memory 4-MB External Cache for 600-MHz models
8-MB External Cache for 750- and 900-MHz models
Main Memory
Capacities

Eight Sun 232-pin Sdram DIMM slots; 2 banks of 4, 4 DIMMs per bank (recommended that DIMMS added in groups of four)

128-MB, 256-MB, and 1-GB DIMMs

8-GB maximum, ECC error correction

Standard Interfaces
Audio Four audio ports: headphone(out), line-in, line-out and microphone(in) using EIA standard 0.125-inch (3.5-mm) jacks
Ethernet One ethernet/fast ethernet (10BASE-T/100BASE-T) twisted-pair standard connector (RJ-45), self-sensing
FC-AL One Fibre Channel Arbitrated Loop (FC-AL) connector
IEEE 1394 Two IEEE 1394 (6-pin) connectors
Keyboard and mouse USB (uses one of the four standard USB (Type A) ports)
Parallel One IEEE 1284 (bidirectional) parallel port (DB25)
PCI

Four 64-bit PCI slots, full-size, three at 33 MHz, one at 66-MHz

SCSI One single-ended, 68-pin, SCSI connector (16-bit Ultra/Fast/Wide, 40-MB/sec)
Serial

Two RS-232C/RS-423 serial ports (DB25)

UPA graphics slot Two UPA graphics slots
USB Four standard Universal Serial Bus (USB) Type A connectors
Internal Mass Storage
Disks Up to two 18-, 36- or 73-GB, 10K rpm FC-AL disk drive
Floppy disk Optional 3.5-in. 1.44-MB floppy
DVD-ROM

Optional 10X-speed DVD-ROM

Tape Optional 12-24GB 4-mm DDS-3 tape Drive
Environment
AC input 100 - 240 VAC, 47 - 63 Hz, 8 A(max), 0.875 KVA
Input power 670 W
Heat output 2286 BTU/hr
Temperature Operating: 5° C to 40° C (41° F to 104° F) without tape drive; 5° C to 35° C (41° F to 95° F) with tape drive
Nonoperating: -40° C to 60° C (-40° F to 140° F)
Humidity Operating: 20% to 80% relative humidity, noncondensing
Nonoperating: 5% to 93% relative humidity, noncondensing
Altitude Operating: 3000 m (10,000 ft)
Nonoperating: 12,000 m (40,000 ft)
Acoustic noise Operating: 5.64 bels
Idling: 4.77 bels
Vibration Operating: 0.2 G peak, three mutually perpendicular axes, 5 to 500 Hz
Nonoperating: 1.0 G peak, all axes, 5 to 500 Hz
Shock Operating: 5.0G for 11 milliseconds, half-sine pulse
Nonoperating: 30G for 11 milliseconds, half-sine pulse
Number of cords 1
Regulations
Meets or exceeds the following requirements:
Safety UL 1950, CSA C22.2 No. 950, TUV EN 60950, CB Scheme with Nordic deviations, EMKO-TSE (74-SEC) 203, ZH1/618
RFI/EMI FCC Class B, DOC Class B, VCCI Class 2, EN 55022 Class B, EN 61000-3-2
Immunity EN 50082-1
X-ray DHHS 21 Subchapter J; PTB German X-ray Decree
Power management Energy Star compliant
Dimensions and Weights
Height 45.5 cm (17.9 in.)
Width 25.4 cm (10.0 in.)
Depth 61.0 cm (24.0 in.)
Weight 32 kg. (70 lbs.)